Skip to content
Industrial solar EPC service by Voltmen Solar: rooftop solar plant on a factory shed in Gurgaon
FactoriesEPC Turnkey

Industrial Solar EPC Company in Gurgaon

Industrial solar EPC in Gurgaon for factories and warehouses: load study, roof check, design, procurement, installation, net metering and O&M by one team.

Inquiry for Industrial Solar EPC

Our engineer will WhatsApp you within 30 minutes (9 am – 8 pm). No spam.

Flexible Financing Available
Fast Installation TAT

Technical Specifications

  • Service ScopeEngineering, procurement and construction
  • Roof TypesMetal sheet, RCC and elevated structure
  • InvertersString inverters, on-grid
  • ElectricalDC and AC cabling, LT panel integration, earthing, lightning protection
  • MeteringNet metering as per current HERC and DHBVN rules
  • Funding ModelsCAPEX or OPEX / RESCO
  • PricingAfter site survey and load study
  • AMCFrom ₹1,000 per month, priced after survey

Why Choose Our Industrial Solar EPC?

Industrial solar EPC in Gurgaon for factories and warehouses: load study, roof check, design, procurement, installation, net metering and O&M by one team.

One EPC Team, No Sub-Contracting

Design, supply, installation and commissioning are handled by Voltmen engineers, so one team answers for the whole plant.

Load Study From 12 Months of Bills

The plant size is worked out from your sanctioned load, daytime consumption and usable roof, not from a fixed package.

Roof and Structure Check

We check the structural load, sheet condition and shadows on metal sheds, RCC roofs and elevated structures before a layout is finalised.

LT Panel Integration

Inverters are tied into your LT panel with proper protection, earthing and lightning protection, and tested before handover.

CAPEX or RESCO Models

You can buy the plant outright (CAPEX) or look at an OPEX / RESCO arrangement, with tax treatment as advised by your CA.

O&M and Remote Monitoring

After commissioning you get monitoring access and an AMC from ₹1,000 per month, priced after a survey, with waterless robotic cleaning offered.

Get a Detailed Engineering Audit

Our engineers will visit your site, check shadows, roof or structure and load, and give you a written quote. The survey is free and carries no obligation.

Book My Free Audit

Industrial solar EPC company in Gurgaon: what it is and who it is for

An industrial solar EPC company in Gurgaon takes full responsibility for a factory or warehouse solar plant, from the first load study to the day the plant is running, and for years after. EPC means engineering, procurement and construction. You deal with one team instead of separate designers, suppliers and electricians.

This page is written for a plant head, factory owner or admin manager who is comparing contractors. It explains what happens at each stage, what you receive, and what we check before we give a quote. Voltmen Solar has 40+ in-house engineers, does no sub-contracting and is MNRE-registered (MNRE/HR/GUR/2024/082).

If you also want to read about offices, schools and hospitals, see our wider industrial and commercial solar page. This page stays with the EPC process for industry, so you can judge a proposal line by line.

Looking at offices, schools or hospitals too? Industrial and commercial solar overview.

The EPC stages and what you receive at each one

Each part of EPC has its own output. Knowing these outputs helps you compare two quotes on equal terms, because a low price often hides a missing stage.

EPC stages for an industrial rooftop solar plant
StageWhat happensWhat you receive
EngineeringLoad study, roof survey, shadow check, plant sizing and electrical designPlant size, array layout, single-line diagram and bill of quantities
ProcurementModules, string inverters, structures, cables and protection gear are ordered and inspected on arrivalAn approved equipment list with brands and warranties
ConstructionStructure fixing, DC and AC cabling, LT panel work, earthing and lightning protectionA plant built to the approved drawings
ApprovalsNet-metering file and inspection as per the current HERC and DHBVN rulesCopies of the application and discom correspondence
CommissioningTesting and grid synchronisationTest records, monitoring access and operating guidance
O&MCleaning, inspection and fault supportService visits and generation reports

Metal sheet, RCC and elevated roofs: what we check before quoting

Industrial roofs are not all the same, and a fair quote depends on reading the roof correctly. On every site we check the same three things: how much weight the roof can take, what condition it is in, and where shadows fall.

Industrial roof types and the checks we make
Roof typeUsual mountingWhat is checked
Metal sheet shedRail and clamp fixing on the sheet or purlinSheet condition, rust, purlin spacing and load, and leak risk at fixing points
RCC roofElevated galvanised structure, anchored or ballastedSlab load capacity, waterproofing, parapet height and roof access
Elevated structureA raised frame that leaves the roof or yard usableColumn loads, wind exposure and a walkway for cleaning

Shadow comes from chimneys, water tanks, taller neighbouring sheds and your own roof equipment. We model it across the day and the seasons, because a shaded string can pull down the output of everything connected to it.

Rooftop solar plant on a large warehouse in a logistics park
Rooftop solar on a warehouse. Illustrative image.

How the solar plant size is decided for your factory

The right size comes from four inputs, not from a standard package. We do not fix a size before the survey.

A plant sized to daytime use is simpler to approve and simpler to run. Your own bills, not a rule of thumb, decide the final number.

As a general guide, a solar plant makes 120 to 180 units per kW per month, depending on season, shading and cleaning. We use this range only as a starting point. The proposal shows the expected generation for your roof, with the assumptions written down so that you can check them.

If your production runs in shifts, tell us. A unit that works only at night gains little from solar, while a unit with strong daytime loads such as motors, compressors, cooling and lighting gains the most.

  • Sanctioned load: the contract load on your connection sets the outer limit of what is practical.
  • Daytime consumption: we read 12 months of bills to see how much power you use while the sun is up, because that is the power the plant replaces.
  • Roof area: the usable, shadow-free area decides how many modules fit.
  • Discom limits: the capacity allowed on your connection is as per the current HERC and DHBVN rules, and we confirm it before design.

Electrical scope: from the modules to your LT panel

The electrical work is where an industrial plant differs most from a home system. A factory has three-phase loads, long cable runs and machines that must not be disturbed. Our scope covers the whole path from roof to panel.

  • String inverters sized to the array and placed where they stay cool and easy to reach
  • DC cabling from the modules to the inverters, routed and protected properly
  • AC cabling and integration with your LT panel through the correct breakers and metering
  • Earthing for the structure, the modules and the inverters
  • Lightning protection suited to a tall metal or RCC building
  • Monitoring of generation and alarms, remotely and on site

CAPEX or RESCO for a solar plant at your industrial unit

You can fund the plant in two general ways. The better one depends on your cash position, your tax planning and how long you will stay in the building.

If you rent your premises, check the lease first. A plant you own sits on a roof you may not control for long, and a RESCO agreement usually needs the landlord to agree to the term.

CAPEX and RESCO / OPEX compared in general terms
PointCAPEXRESCO / OPEX
Who pays for the plantYouA developer
Who owns itYouThe developer, usually for an agreed term
How you payA one-time cost, then O&MA rate per unit under an agreement
SavingsStay with youShared through the rate you agree
Tax treatmentAs advised by your CAAs advised by your CA

Voltmen does not give tax advice. Ask your CA how either option affects your books before you decide.

Safety, documentation and net metering for industrial connections

Work at height on factory roofs needs discipline. Our engineers follow site safety rules, and we agree access and shutdown windows with your plant team so that production is not disturbed.

Net metering for an industrial connection goes through your discom, which for Gurgaon is DHBVN. The file, meter testing and inspection are handled as per the current HERC and DHBVN rules, and the approved capacity and billing terms are set by those rules, not by us. Time taken depends on the capacity and the checks needed, so we give you a schedule only after the survey.

At handover you receive the drawings, test records, equipment warranty details and monitoring access, so your maintenance team has a proper record to work from.

Panels carry a 12-year product warranty and a 25 to 30-year linear power warranty, as per brand. Our workmanship warranty is 2 years. Keep these papers with your plant file, because your insurer, auditor or a future buyer of the unit may ask for them.

Before the plant is switched on, we test the strings, the inverters, the protection devices and the earthing, and we record the readings. This record is useful later if you ever need to compare how the plant performs against its first day.

Want the step-by-step net metering guide? DHBVN net metering process.

O&M and waterless cleaning after commissioning

Dust from roads and factory processes settles quickly on panels in Gurgaon. Regular cleaning and inspection protect the output you paid for.

Large industrial arrays are hard to wash by hand and unsafe to walk on when wet. That is why walkways in the design and a proper cleaning method matter as much as the panels themselves.

Our AMC starts from ₹1,000 per month and is priced after a survey. It covers cleaning and inspection visits. We also offer waterless robotic panel cleaning, which suits large roofs and sites where water use is a concern.

See AMC and cleaning options. Solar maintenance and cleaning.

Industrial solar installation near IMT Manesar and Udyog Vihar

We install rooftop solar plants for factories and warehouses around Gurugram, including IMT Manesar and Udyog Vihar. Our references are a 100 kW on-grid plant at IMT Manesar and a 150 kW on-grid plant at Pace City 2, Sector 37. Plants of this size are priced only after a site survey and load study, so we do not quote a rate per kW here.

To begin, send us your last 12 months of electricity bills and the location of your unit. We will visit, check the roof and come back with a written proposal.

Ready to begin? Request a site survey.

Our Process

How It Works

From your first call to a fully commissioned system — here is exactly what to expect.

01

Load Study and Site Survey

We read 12 months of your bills, note your sanctioned load and daytime demand, and walk the roof to check area, structure, sheet condition and shadows.

02

Engineering and Quote

You receive the plant size, array layout, single-line diagram and a written quote with the bill of quantities, priced after the survey and load study.

03

Procurement

Modules, string inverters, structures, cables and protection gear are ordered against the approved design and checked on arrival.

04

Construction

Voltmen engineers fix the structure, lay DC and AC cabling, connect the LT panel and complete earthing and lightning protection, working to site safety rules.

05

Net Metering and Commissioning

We prepare the discom file as per the current HERC and DHBVN rules, test the plant and synchronise it with the grid.

06

Handover and O&M

You get drawings, test records and monitoring access, followed by AMC and cleaning support if you choose it.

Recent Industrial Solar EPC
Installations

View All
100 kW on grid industrial solar plant at IMT Manesar by Voltmen Solar

IMT Manesar

100 kW On-Grid Industrial Solar Plant

Turnkey on-grid industrial rooftop plant for a manufacturing facility, with aluminium rail mounting and HT/LT electrical synchronisation.

150 kW on grid industrial solar plant at Pace city 2, Sector 37, Gurgaon by Voltmen Solar

Pace City 2, Sector 37, Gurgaon

150 kW On-Grid Industrial Solar Plant

Industrial rooftop plant for a large commercial facility, with elevated column structures and DHBVN net-metering integration.

Questions Answered

Industrial Solar EPC Company in Gurgaon: FAQs

What does EPC mean in industrial solar?

EPC stands for engineering, procurement and construction. One company designs the plant, buys the equipment, builds it and commissions it. You get a single point of responsibility instead of managing separate vendors. Voltmen Solar does this work with its own engineers and no sub-contracting.

How much does an industrial solar plant cost?

It depends on plant size, roof type, structure and your electrical setup, so we price only after a site survey and load study. We do not quote a rate per kW for industrial plants without seeing the site. You receive a written quote with a bill of quantities.

Can my metal sheet shed take solar panels?

Often yes, but it must be checked first. We look at the sheet condition, rust, purlin spacing and the load the roof can carry, and at leak risk where fixings go through. If the shed is weak, an elevated structure or repair work may be advised.

How do you decide the size of a factory solar plant?

We combine four things: your sanctioned load, daytime consumption from 12 months of bills, usable shadow-free roof area, and the limits on your connection as per the current HERC and DHBVN rules. The result is a plant sized to your site, not a standard package.

Should I choose CAPEX or RESCO?

With CAPEX you buy and own the plant. With RESCO or OPEX a developer owns it and you pay per unit. The right choice depends on cash, tax planning and how long you will occupy the building. Please discuss the tax side with your CA before deciding.

Will solar installation disturb my production?

We plan work to keep disturbance low. Roof work happens above the production floor, and the connection to your LT panel is done in a shutdown window agreed with your plant team. Safety rules for work at height are followed on site throughout.

Is net metering available for industrial connections?

Net metering for industrial connections is handled through DHBVN as per the current HERC and DHBVN rules. We prepare the file, coordinate meter testing and inspection, and support you until the plant is synchronised. Approved capacity and billing terms are set by those rules.

What electrical equipment is included in the scope?

The scope covers modules, string inverters, mounting structure, DC and AC cabling, LT panel integration, earthing, lightning protection and monitoring. The exact bill of quantities depends on your site and is shared with the quote, so you can see what you are paying for.

What does maintenance cost after commissioning?

Our AMC starts from ₹1,000 per month, with the final price set after a survey based on plant size and roof access. We also offer waterless robotic panel cleaning for large roofs. Regular cleaning helps the plant keep generating well in dusty conditions.

Which areas around Gurgaon do you serve for industry?

We work with factories and warehouses across Gurgaon, including IMT Manesar and Udyog Vihar. Our industrial references are a 100 kW plant at IMT Manesar and a 150 kW plant at Pace City 2, Sector 37. Call +91 9540003075, Monday to Saturday, 9 AM to 8 PM.

Call HelplineFree Consultation